Plan responsibly
Before You Build
This project may be subject to local permit, zoning, site, or structural requirements.
- Require qualified load analysisVerify project-specific load inputs through qualified local analysis.
- Require equipment reviewVerify equipment performance, controls, utilities, venting, and installation separately.
- Verify local requirementsConfirm adopted code, amendments, permits, inspections, and manufacturer requirements locally.
General guidance only: This does not establish adopted local law. It is user-entered arithmetic, not a load calculation, equipment selection, or duct design.
Not Manual J: This does not replace a project load calculation.
Not equipment selection: Nominal tons are a unit conversion only, not equipment selection.
Local requirements may differ. No project-specific model-code reference is asserted here.
Methodology
How we calculate this
Inputs are limited to hundredth increments. Multiply conditioned area by each user-entered density, add each labeled known load once to both endpoints, and divide by one minus the optional user-entered derating percentage using exact scaled-BigInt arithmetic. Known, source, planning, and derating-effect outputs round half up to whole Btu/h. Each nominal-ton conversion is independently calculated from the exact ratio and rounded half up to 0.001 nominal ton; these public number scales are proven safe throughout the accepted input bounds.
planning Btu/h = (area × entered density + Σ separately known loads) ÷ (1 − entered derating/100); nominal tons = planning Btu/h ÷ 12,000
Why the house details matter
Insulation slows heat loss and heat gain. Windows can add heat gain in summer and heat loss in winter. Climate affects how much heating and cooling the home needs, while air leakage adds load by letting outdoor air in. Because those details are project-specific, Advanced density values must come from a qualified source.
Do not double count known loads
Enter only labeled loads that are not already represented in the source density range. A single entered Btu/h value is added once to both endpoints.
Treat derating as user-supplied arithmetic
A 10% entry means nominal capacity is treated as delivering 90% of nominal. The tool does not infer derating from altitude, climate, fuel, voltage, equipment, or model number.
Get qualified local design
Orientation, envelope, infiltration, ventilation, occupant and internal gains, ducts, sensible and latent load, climate design conditions, actual equipment performance, electrical/fuel scope, code, permit, and inspection require qualified local analysis.
Sources
Assumptions and references
Last reviewed: 2026-08-24